Distribution Lines

Live Part Cover

 
 
 

Introduction

According to the global climate change issue, many utilities and the Public Limited Companies are planning to grow more and more trees and living friendly with animal such as birds, squirrels, etc. These cause a lot of electricity blackouts mainly to the overhead line power distribution system, other causes from lightning, strong wind, raining, chemical pollution and trees themselves. Each time of blackout, it costs utility not only a large amount of expense but also the reputable of reliability will be questioned and lead to the compensation and exchanging of the electricity supplier.


In conventional overhead 12-33 kV distribution construction system, it is clearly seen that most of the terminal points for electricity path are not completely covered with outdoor insulation products, so we offer a complete ranges of barriers / deterrents / insulation, cost effective, and reliable means to protect their substation and overhead line assets from bird, squirrels, snakes and other environmentally induced flashovers such as lightning and tree touching, etc. The material shall be specified all types of polymer which are designed and tested to be quick installation, no special tools, UV stable, non-tracking, abrasion resistant and high dielectric strength withstand.


The Thai electricity utility has been proving our products and confirms to improve service level, reduce the environmental risk, maintain customer satisfaction and increase equipment life expectancy which leads to protect his own expensive assets.


Features

The equipment shall have successfully passed all the type tests or design tests in accordance with the Thai Industry Standards and the following international standards:

  • IEC Publication 60695 - 11 - 10 : Fire hazard testing - Part 11 - 10 : Test flames - 50 W horizontal and vertical flame test methods
  • IEC 60332-3-22:2000 Tests on electric cables under fire conditions – Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category A
  • IEC Publication 60243 - 1 : Electrical strength of insulating materials - Test methods - Part I : Tests at power frequencies
  • ASTM Publication D 638 - 03 : Standard test method for tensile properties of plastics
  • TIS Publication 293 : PVC insulated aluminium cables
  • ASTM D3554 - 07 Standard Specification for Track-Resistant Black Thermoplastic High-Density Polyethylene Insulation for Wire and Cable, 75 °C Operation

All the products shall be completely passed the routine test before delivery to the local and oversea customers.

Type

  • Cable guard
  • Rubber hose
  • Fuse cutout cover
  • Bird protection devices
  • Bushing cover (Transformers, Instrument transformers, Capacitor, Surge arresters)
  • Animal barrier